RFL SMX3 / 21 Page 14 of 22 Issue 1.4
User Manual
08 June 2009
DIP Switch 1 settings:
SW 1 X.21 Data Channel A Configuration
8 7 6 5 4 3 2 1
Bandwidth
Not
Used
Always
set to 0
Not
Used
Local Loop Indicate Port Enable
00 = 64K 0= Off 0= Local 0= Off
01 = 128K
1= On
(Test only)
1= Remote 1= Enabled
10 = Not Used (See Note
11 = Not Used Section 8)
Bandwidth
Set to 64kbit/s, or 128kbit/s if permitted by the speed of the aggregate (refer to table in
section 5).
Local Loop Off / On.
Normally set to Off
When set to On, data transmitted into of the MUX TxD is looped back to its RxD output.
Channel A requires the clock to be present; as this is a DCE port the clock is sourced
from the MUX; provided this is present local loop operation is always possible.
Indicate
When set to Local, I is ON when the channel is legally configured, the aggregate is
running and in sync, in which case C is ignored
When set to Remote, I is ON when the channel is legally configured, the aggregate is
running and in sync, and C is received from the remote end
.
Channel Enable.
Set to On to enable Channel A X.21 Data Channel
c
X.21 Aggregate Channel
SMX3-21
A
C
B
TxD
RxD
DCE
MUX
Data Channels